תיאור
Logger w/Cable
Measurement Range:
4-20mA (w/CABLE-4-20MA) 0 to 20.1 mA
0 to 2.5 V (w/CABLE-2.5-STEREO)
0 to 5 V (w/CABLE-ADAP5)
0 to 10 V (w/ CABLE-ADAP10)
0 to 24 V (w/ CABLE-ADAP24)
Accuracy:
4-20mA ±0.001 mA ±0.2% of reading (w/CABLE-4-20MA)
±0.1 mV ±0.1% of reading (w/CABLE-2.5-STEREO)
±0.2 mV ±0.3% of reading (w/CABLE-ADAP5)
±0.4 mV ±0.3% of reading (w/ CABLE-ADAP10)
±1.0 mV ±0.3% of reading(w/ CABLE-ADAP24)
Resolution:
0.3 µA 4-20mA (w/CABLE-4-20MA)
40 µV (w/CABLE-2.5-STEREO)
80 µV (w/CABLE-ADAP5)
160 µV (w/ CABLE-ADAP10)
384 µV (w/ CABLE-ADAP24)
Logger
Operating Range Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing);
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Logging Rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging Modes: Normal, burst, or statistics
Memory Modes: Wrap when full or stop when full
Start Modes: Immediate, push button, date & time, or next interval
Stop Modes: When memory full, push button, or date & time
Restart Mode: Push button
Time Accuracy: ±1 minute per month at 25°C (77°F), see Plot A
Battery Life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery Type: Two AAA 1.5 V alkaline batteries, user replaceable
Memory: 4 MB (1.9 million measurements, maximum)
Download Type: USB 2.0 interface
Full Memory Download Time: Approximately 1.5 minutes
LCD: LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.)
Weight: 107.5 g (3.79 oz)
Environmental Rating: IP50
– The CE Marking identifies this product as complying with all relevant directives in the European Union (EU).